biacore 2000 instrument (Biacore)
86
Structured Review
Biacore
biacore 2000 instrument
Biacore 2000 Instrument, supplied by Biacore, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biacore+2000+instrument/2000+biacore+instrument/us12622978-234-43-43
Average 86 stars, based on 1 article reviews
Biacore 2000 Instrument, supplied by Biacore, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/biacore+2000+instrument/2000+biacore+instrument/us12622978-234-43-43
Average 86 stars, based on 1 article reviews
biacore 2000 instrument - by Bioz Stars,
2026-09
86/100 stars
Images
Related Articles
Binding Assay:Article Title: Recombinant cell surface capture proteins Article Snippet: .. Measurements to determine binding affinities and kinetic constants were made on a Article Title: Anti-L1CAM antibodies and uses thereof Article Snippet: .. Typically, the antibody (i) binds with an equilibrium dissociation constant (KD) of approximately less than 10−7 M, such as approximately less than 10−8 M, 10−9 M or 10−10 M or even lower when determined by, e.g., surface plasmon resonance (SPR) technology in a Article Title: Binding agents and uses thereof for central nervous system delivery Article Snippet: .. Typically, the antibody binds with an equilibrium dissociation constant (KD) of approximately less than 10−6 M, such as approximately less than 10−7, 10−8 M, 10−9 M or 10−10 M or even lower when determined by, e.g., surface plasmon resonance (SPR) technology in a SPR Assay:Article Title: Anti-L1CAM antibodies and uses thereof Article Snippet: .. Typically, the antibody (i) binds with an equilibrium dissociation constant (KD) of approximately less than 10−7 M, such as approximately less than 10−8 M, 10−9 M or 10−10 M or even lower when determined by, e.g., surface plasmon resonance (SPR) technology in a Article Title: Anti-met antibodies, bispecific antigen binding molecules that bind met, and methods of use thereof Article Snippet: .. 20) (maytansinoid B) were determined using a real-time surface plasmon resonance biosensor assay on a Article Title: Binding agents and uses thereof for central nervous system delivery Article Snippet: .. Typically, the antibody binds with an equilibrium dissociation constant (KD) of approximately less than 10−6 M, such as approximately less than 10−7, 10−8 M, 10−9 M or 10−10 M or even lower when determined by, e.g., surface plasmon resonance (SPR) technology in a Article Title: Anti-family with sequence similarity 19, member A5 antibodies and method of use thereof Article Snippet: .. As used herein, an antibody that “binds specifically” to an antigen refers to an antibody that binds to the antigen and substantially identical antigens with high affinity, which means having a KD of 10−7 M or less, preferably 10−8 M or less, even more preferably 10−9 M or less, and most preferably between 10−8 M and 10−10 M or less, when determined by, e.g., immunoassays (e.g., ELISA) or surface plasmon resonance (SPR) technology in a Recombinant:Article Title: Anti-L1CAM antibodies and uses thereof Article Snippet: .. Typically, the antibody (i) binds with an equilibrium dissociation constant (KD) of approximately less than 10−7 M, such as approximately less than 10−8 M, 10−9 M or 10−10 M or even lower when determined by, e.g., surface plasmon resonance (SPR) technology in a Article Title: Calreticulin-Mediated Quality Control of the Non-Classical MHC-I Molecule MICA: Implications for Immune Surveillance. Article Snippet: The BIAcore Sensor Chip CM5 (BIAcore, Uppsala, Sweden) was conjugated with a concentration of 1 μg/μL of recombinant MICA protein obtained in 10 mM HEPES pH 7.5, 150 mM NaCl, 0.05% Tween buffer, with a maximum sample volume of 200 μL. .. The analyte (recombinant CRT) was applied at concentrations of 1 nM, 5 nM, and 20 nM using the Article Title: Calreticulin-Mediated Quality Control of the Non-Classical MHC-I Molecule MICA: Implications for Immune Surveillance Article Snippet: The BIAcore Sensor Chip CM5 (BIAcore, Uppsala, Sweden) was conjugated with a concentration of 1 μg/μL of recombinant MICA protein obtained in 10 mM HEPES pH 7.5, 150 mM NaCl, 0.05% Tween buffer, with a maximum sample volume of 200 μL. .. The analyte (recombinant CRT) was applied at concentrations of 1 nM, 5 nM, and 20 nM using the Biosensor Assay:Article Title: Anti-met antibodies, bispecific antigen binding molecules that bind met, and methods of use thereof Article Snippet: .. 20) (maytansinoid B) were determined using a real-time surface plasmon resonance biosensor assay on a Enzyme-linked Immunosorbent Assay:Article Title: Anti-family with sequence similarity 19, member A5 antibodies and method of use thereof Article Snippet: .. As used herein, an antibody that “binds specifically” to an antigen refers to an antibody that binds to the antigen and substantially identical antigens with high affinity, which means having a KD of 10−7 M or less, preferably 10−8 M or less, even more preferably 10−9 M or less, and most preferably between 10−8 M and 10−10 M or less, when determined by, e.g., immunoassays (e.g., ELISA) or surface plasmon resonance (SPR) technology in a RIA Assay:Article Title: Claudin-6-specific immunoreceptors and T cell epitopes Article Snippet: .. Affinities may be readily determined using conventional techniques, such as by equilibrium dialysis; by using the |